Research on Energy-saving Design for University Library Spaces in Cold Regions

FANZhengyu, SUNDongxian, LIUJiaping

Abstract


With the popularization of open-shelf reading in university library, the change of use mode leads to the change of space mode, and gradually develops from corridor mode to large-scale and deep composite centralized space organization mode. However, the large and deep open reading space and atrium space in university libraries increasingly rely on artificial lighting, mechanical ventilation and mechanical temperature regulation to meet the comfort needs of space thermal environment. Moreover, the improper control of passive design strategy in the early stage further leads to the reduction of indoor thermal environment comfort and the increase of building energy consumption. In the early stage of architectural design, through reasonable passive space layout design, the use of air conditioning equipment can be greatly reduced, energy consumption can be reduced, and the goal of green development can be achieved. Through extensive collection and analysis of 23 university libraries built in cold climate region, by making a statistical study on the building type, building area, number of floors, building scale and building plane aspect ratio, summarizing and extracts the prototype. Referring to the typical cases in cold climate area, two core groups that reading spatial variable group and atrium spatial variable group are proposed by controlling a single variable, in which each group has four plane layout modes. The dynamic energy consumption simulation software DesignBuilder is used to simulate the annual cooling, heating and lighting load of each group in cold climate region, and the results are converted into energy consumption values for analysis. The final results show that among the four combination modes of reading spatial variable group, the overall energy consumption of compound type is the smallest, and the energy-saving rate is the highest, up to 3.71%. The overall energy consumption of parallel type and surround type is little difference, and the overall energy consumption of surround type is the highest. The energy-saving rate of the four groups of reading modes is as follows: compound type > decentralized type > parallel type > surround type. The total energy consumption of the atrium partial staggered floor group is lower than that of the non staggered floor group. Among the four combination modes of the atrium spatial variable group, the overall energy consumption of the organization form of the atrium partial staggered floor to the south is the smallest, the energy-saving rate is the highest, reaching 5.84%, and the energy-saving rate of the atrium partial staggered floor to the north is the lowest. Therefore, in the preliminary scheme design stage, low-performance spaces such as traffic auxiliary space can be placed at the building boundary to form a buffer zone similar to the transition space, so as to alleviate the negative impact of the external adverse climate environment on the internal space. At the same time, it can be considered to carry out partial staggered floor design of the atrium, and give priority to arranging the atrium on the south side, which is not only conducive to reducing the overall energy consumption of the building and achieving the energy-saving goal, but also enhance the diversification of vertical sections and promote the interest of the internal space of modern university libraries.

Keywords


university library; functional organization; energy consumption simulation; energy saving design

Full Text:

PDF

References


BAO Jiasheng. Architectural Design of Modern Library[M]. Beijing: China Architecture Industry Press, 2002.

CHENG Taining, ZHONG Chengxia. The Renewal and Development of the Architectural Design Concept of the Library:Design Exploration of the Ningbo Higher Education Park Library and Information Center[J].Architecture Journal,2007,465(5):70-73.

MEIFANG ZHANG, YUSHI WANG. Energy efficiency approaches in archives and library buildings in China[J]. Archival science,2015,15(1):71-81.

RONG MAO.ZHENG, GUI XIONG.LIU, YUE HUA. XU. Smart Lights Technology Used in Library Energy-Saving[J]. Advanced Materials Research,2013,2569(1546):227-232.

MAO Zhuoying, XIAO Dawei, SHAO Song. Breaking through traditional thinking and norms to discuss library space design[J]. Southern Architecture,2020(1):41-46.

BAI Chaoren. Research on Passive Energy Saving Strategy of Library Buildings Based on BIM[D]. Harbin: Harbin Institute of Technology, 2019.

LUO Lin. The energy-saving design strategy of academic libraries in severe cold areas based on learning efficiency[D]. Harbin: Harbin Institute of Technology,2018.

HAN Dongqing, GU Zhenhong, WU Guodong. Study of Methods of Designing Public Buildings of Climatic Adaptability Centered Around Spatial Form[J]. Architecture Journal, 2019(4):78-84.

CUI Kai. Design Technology System for Region and Climate Adaptive Green Public Buildings[M]. Beijing: China Architecture Industry Press, 2021.

China Architecture Northwest Design and Research Institute Co., Ltd. Library Architectural Design Code JGJ38-2015[M]. Beijing: China Architecture Industry Press,2015.

SHENG.CANG. Energy Efficiency Renovation Study of a University Library Building in Ningbo[J]. Advanced Materials Research,2014,3149(1840):1703-1706.

PAN Yudan, QIU Jianfa, BAO Ying. A new interpretation of the ancient charm of Muzhai ancient pavilion:an architectural conception of Nankai University Library[J]. South Architecture,2013(4):116-118.

JIAN LI.LIU. Renewable Energy Technologies for University Library Building[J]. Applied Mechanics and Mat erials,2012,1802(359):155-159.

China Academy of Building Research. JGJ/T 449-2018 Civil Building Green Performance Calculation Standard[S]. Beijing: China Building Industry Press, 2018.

CHENG Rui, WANG Xin, ZHANG Yinping. New ideas and new methods for constructing sustainable building e n e r g y s t o r a g e e n v e l o p e s t r u c t u r e [ J ] . S o u t h Architecture,2012(1):86-91.

China Academy of Building Research. GB 50189-2015 Design Standard for Energy Efficiency of Public Buildings[S]. Beijing: China Building Industry Press, 2015.

REN Lizhi, LI Chujing, CHEN Xianglei.Both Square and Circle: Library Design Practice of Two University Campuses[J]. South Architecture,2012(3):45-48.

LEI Tao. Research on Computer Simulation of Atrium Space Ecological Design Strategy[D]. Beijing: Tsinghua University,2004.

SUN Cheng, ZHI Dong-yi, HAN Yun-song. Design Strategy of Teaching Building Group in the Cold Zone Based on Outdoor Thermal Comfort[J].South Architecture,2020(4): 80-85.




DOI: https://doi.org/10.33142/jsa.v1i1.10434

Refbacks

  • There are currently no refbacks.